Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Hefei Coolnet power Co., ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

  • 1
  • 2
  • 3

Brand Name : COOLNET

Model Number : XR012A, XR040A

Certification : CE,ISO

Place of Origin : CHINA

MOQ : 1set

Price : 1800-30000USD

Payment Terms : T/T, L/C

Supply Ability : 300 PCS PER MONTG

Delivery Time : 10-25 working days

Packaging Details : Packed in plywooden case, standard export package

Cooling capacity : 12kw- 40kw

Condition : Brand New

Mounting : Floor Standing Units

Type : In-Row Air Cooling Unit

Operating voltage : 380/400 VAC,230 VAC,220V

Warranty : 1 Year(12 month )

Product name : Precision Air Conditioning Units

Refrigerant : R22(R407C/R410A)

Application : Data Center, IT room , Computer room, Data Center Cold/hot aisle

Color : Black/Grey/White/Other custom colors

Fan type : EC fan

Power : 3N-380V-50Hz,220v/50hz/60hz

Airflow : 2000~40000 m3/h

Power Supply : 380v/220v,220V/380V,380V/415V

Contact Now

Precise Heat Dissipation In-Row Air Cooling Units With Large Volume For Data Centers

Product Introduction

The determinant air conditioner is a cooling device arranged in the cabinet rack and installed side by side with the server cabinet. When adjusting the temperature of the entire internal space of the computer room, the traditional air conditioner is generally far away from the heat source, the effect is uneven, and the energy consumption is large. The biggest feature of the in-line air conditioner is that it can be close to the heat source and directly dissipate the heat of the heat source. Its heat dissipation efficiency is higher, which is more conducive to energy saving. Therefore, the use of determinant air conditioners for heat dissipation in computer room cabinets has been more and more widely used.

Feature & Benefits

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Applicatinon Range

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers
  • Mobile base station
  • Outdoor rooms
  • Satellite ground station
  • Paging machine room
  • Network management center
  • Small computer room
  • Small laboratory
  • Wine cellar

Structure & Components

DC Inverter Compressor of DX System

Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability

Backward Centrifugal EC Fan

Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;

Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;

Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;

Soft start function, low starting current; Easy maintenance design

Electronic Expansion Valve

Smoothly adjust the throttle opening, matched with variable capacity compressor To achieve energy saving;

Wide adjustment range, reduce superheat and improve energy efficiency ratio Reduce cooling capacity and load;

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Technical Parameter

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

Certificates

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Factory Details

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Packing and Delivery

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Cases

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers


Product Tags:

Heat Dissipation In Row Cooling Unit

      

Precise In Row Air Conditioning Unit

      

R22 In Row Cooling Unit

      
Best Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers wholesale

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hefei Coolnet power Co., ltd
*Subject:
*Message:
Characters Remaining: (0/3000)